APPLICATION
The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 65.6’ (20m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or HART communicator. The non-contact liquid level sensor is intended for chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a flange fitting. Typical applications include bulk storage and process tanks.
FEATURES
- 316L antenna with PTFE inner shield for corrosive media
- Configuration via push button display or HART communicator
- 26 GHz. pulse radar is unaffected by vapor or condensation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- Auto-temperature compensation for accurate measurement
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- IP67 stainless enclosure with polycarbonate display window
PRICING
P/N | Description | From |
---|---|---|
LR21-5321-30-00 | 3″ ANSI flange, 316L w/PTFE shield | $3,000.00 |
LR21-5321-40-00 | 4″ ANSI flange, 316L w/PTFE shield | $3,100.00 |
LB12-1001 | Intrinsic safety barrier | $1,050.00 |
DOCUMENTATION
Data Sheet | Quick Start | Manual | Control Drawing | CSA Certificate | IECEx Certificate | ATEX Certificate | HART DD Files | 3D Model | Flowline Brochure
SPECIFICATIONS
Range: 12” to 65.6’ (30cm to 20m)
Frequency: 26 GHz.
Accuracy: ± 3mm
Dead band: 12” (30cm)
Beam angle: – 30: 12º, – 40: 8º
Configuration: Push button, HART
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 302º, C: -40º to 150º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 72 psi (-1 to 5 bar)
Enclosure rating: IP67
Encl. material: 316L stainless steel w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector
Antenna material: 316L w/PTFE inner shield
Process mount: – 30: 3” flange (ANSI), – 40: 4” flange (ANSI)
Classification: Intrinsically safe
Approvals: ATEX IIG Ex ia II C T6…T3 Ga; IEC Exia IIC T6…T3 Ga; CSA Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; (T6…T3) Class I Zone 0 AEx ia IIC (T6…T3) Ga Zone 20 AEx ia IIIC (T76ºC to T146ºC) Da Ex ia IIC (T6…T3) Ga Ex ia IIIC (T76ºC to T146ºC) Da
Entity parameters: Install per control drawing #301901
Certification: FCC
Compliance: CE, CRN, RoHS
PRODUCT SELECTION
If you want help in selecting a sensor for your application, please submit a Level Questionnaire. An engineer will review your requirements and suggest a product solution via email.